Product presentation

The CLASSIC range of needle indicators is designed to operate in standard and industrial environments: electrical panels and cabinets, laboratory equipment, etc.

The range is available in several sizes (48, 72 and 96 mm) and several types of measurement quantities, from IP52 to IP55.

Available in numerous standard references.

  • AC ammeter
  • Direct connection or on 1A or 5A CT
  • Normal scale or motor
  • 50 or 60 Hz moving-iron measuring element
  • 50 to 10,000 Hz moving-coil measuring element
  • Deflection 90° or 250°
  • Format 48, 72 or 96
Analogue device

Analogue device

Designed and manufactured

Designed and manufactured

Cost-effective solution

Cost-effective solution

Easy installation

Easy installation

Contact a sales representative

Need information about our solutions? Our experts are available to advise you and assist you with your project. Contact a sales representative now for a detailed presentation and a quote tailored to your needs.

Contact a sales representative

Highlights

  • Reference standard IEC 60051-1
  • Designed for common industrial applications.
  • Technology and cost suitable for manufacturers of machines and electrical switchboards.
  • Numerous items listed.
  • IP52 as standard (IP55 on request)

Features

Function

Classic AC ammeter (CL)

Measurement element

90° deviation

Ferromagnetic, 50 to 60 Hz magnetoelectric with rectifier, 50 to 10,000 Hz

240° deviation

Magnetoelectric with rectifier, 50 to 10,000 Hz

Normal scale

100 mA to 30 A

Engine scale

from 0 to In at 2/3 of the scale, then from 3 to 6 In at the end of the scale (standard value 3 In)

Connection mode

Direct

0 to 30 A

On CT

In: 1 A or 5 A (scale from 0 to 1.3 In)

General specifications

Reference standard

CEI 60051-1

Class index (accuracy class)

01/05/2025

Assembly

On front of panel - Panel thickness 8 mm max.

Format

48x48 mm - 72x72 mm - 96x96 mm

Needle deviation range

90° or 240°

Ingress protection (IP)

IP52 - IP55

Overload ammeter

1.3 In permanent / 10 In for 5 s

Conditions of use

Nominal operating temperature: 23 °C +/- 2 °C.

Operating temperature limit: -25 °C to +50 °C.

Relative humidity: < 90% to 40 °C

Dial Inscription/marking/numbering on request

yes

Documentation and support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

Identify your reference

This downloadable selection guide allows you to identify the item code corresponding to your needs.

CL.AMP.DC_5.png

Add or remove products from your selection directly online, then fill out the form with your contact details. Once your request has been sent, our specialist teams will review it and respond as soon as possible with a solution tailored to your needs.

picto

Classic Ammeter AC 96x96mm 90° 0-2,5/7,5KA TC 2500/5A Class 1,5

10832646

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-2.5/7.5KA TC 2500/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

picto

Classic Ammeter AC 96x96mm 90° 0-3/9KA TC 3000/5A Class 1,5

10832647

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-3/9KA TC 3000/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel, fixed with 2 studs

picto

Classic Ammeter AC 96x96mm 90° 0-4/12KA TC 4000/5A Class 1,5

10832649

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-4/12KA TC 4000/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

picto

Classic Ammeter AC 96x96mm 90° 0-5/15KA TC 5000/5A Class 1,5

10832650

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-5/15KA TC 5000/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

picto

Classic Ammeter AC 96x96mm 90° 0-1,2/3,6KA TC 1200/5A Class 1,5

10832651

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-1.2/3.6KA TC 1200/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

picto

Classic Ammeter AC 96x96mm 90° 0-2/6A Class 1,5

10839503

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-2/6A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel, fixed with 2 studs

picto

Classic Ammeter AC 96x96mm 90° 0-2,5/7,5A Class 1,5

10839504

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-2.5/7.5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

picto

Classic Ammeter AC 96x96mm 90° 0-3/9A Class 1,5

10839505

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-3/9A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

picto

Classic Ammeter AC 96x96mm 90° 0-4/12A Class 1,5

10839506

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-4/12A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

picto

Classic Ammeter AC 96x96mm 90° 0-5/15A Class 1,5

10839507

Classic panel meter AC ammeter - Size 96x96mm - 90° deflection - Measurement range 0-5/15A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Request a quote

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.