Product presentation

The CLASSIC range of needle indicators is designed to operate in standard and industrial environments: electrical panels and cabinets, laboratory equipment, etc.

The range is available in several sizes (48, 72 and 96 mm) and several types of measurement quantities, from IP52 to IP55.

Available in numerous standard references.

  • AC ammeter
  • Direct connection or on 1A or 5A CT
  • Normal scale or motor
  • 50 or 60 Hz moving-iron measuring element
  • 50 to 10,000 Hz moving-coil measuring element
  • Deflection 90° or 250°
  • Format 48, 72 or 96
Analogue device

Analogue device

Designed and manufactured

Designed and manufactured

Cost-effective solution

Cost-effective solution

Easy installation

Easy installation

Contact a sales representative

Need information about our solutions? Our experts are available to advise you and assist you with your project. Contact a sales representative now for a detailed presentation and a quote tailored to your needs.

Contact a sales representative

Highlights

  • Reference standard IEC 60051-1
  • Designed for common industrial applications.
  • Technology and cost suitable for manufacturers of machines and electrical switchboards.
  • Numerous items listed.
  • IP52 as standard (IP55 on request)

Features

Function

Classic AC ammeter (CL)

Measurement element

90° deviation

Ferromagnetic, 50 to 60 Hz magnetoelectric with rectifier, 50 to 10,000 Hz

240° deviation

Magnetoelectric with rectifier, 50 to 10,000 Hz

Normal scale

100 mA to 30 A

Engine scale

from 0 to In at 2/3 of the scale, then from 3 to 6 In at the end of the scale (standard value 3 In)

Connection mode

Direct

0 to 30 A

On CT

In: 1 A or 5 A (scale from 0 to 1.3 In)

General specifications

Reference standard

CEI 60051-1

Class index (accuracy class)

01/05/2025

Assembly

On front of panel - Panel thickness 8 mm max.

Format

48x48 mm - 72x72 mm - 96x96 mm

Needle deviation range

90° or 240°

Ingress protection (IP)

IP52 - IP55

Overload ammeter

1.3 In permanent / 10 In for 5 s

Conditions of use

Nominal operating temperature: 23 °C +/- 2 °C.

Operating temperature limit: -25 °C to +50 °C.

Relative humidity: < 90% to 40 °C

Dial Inscription/marking/numbering on request

yes

Documentation and support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

Identify your reference

This downloadable selection guide allows you to identify the item code corresponding to your needs.

CL.AMP.DC_5.png

Add or remove products from your selection directly online, then fill out the form with your contact details. Once your request has been sent, our specialist teams will review it and respond as soon as possible with a solution tailored to your needs.

Classic Ammeter AC 48x48mm 90° 0-32,5A TC 25/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-32,5A TC 25/5A Class 1,5

10482416

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-32.5A TC 25/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-40A TC 30/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-40A TC 30/5A Class 1,5

10482417

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-40A TC 30/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-52A TC 40/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-52A TC 40/5A Class 1,5

10482418

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-52A TC 40/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-65A TC 50/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-65A TC 50/5A Class 1,5

10482419

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-65A TC 50/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-80A TC 60/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-80A TC 60/5A Class 1,5

10482421

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-80A TC 60/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-100A TC 75/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-100A TC 75/5A Class 1,5

10482423

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-100A TC 75/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-130A TC 100/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-130A TC 100/5A Class 1,5

10482425

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-130A TC 100/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-165A TC 125/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-165A TC 125/5A Class 1,5

10482426

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-165A TC 125/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-200A TC 150/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-200A TC 150/5A Class 1,5

10482428

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-200A TC 150/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Classic Ammeter AC 48x48mm 90° 0-260A TC 200/5A Class 1,5

Classic Ammeter AC 48x48mm 90° 0-260A TC 200/5A Class 1,5

10482430

Classic panel meter AC ammeter - Size 48x48mm - 90° deflection - Measurement range 0-260A TC 200/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with bracket mounting

Request a quote

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.