Product presentation

The CLASSIC range of needle indicators is designed to operate in standard and industrial environments: electrical panels and cabinets, laboratory equipment, etc.

The range is available in several sizes (48, 72 and 96 mm) and several types of measurement quantities, from IP52 to IP55.

Available in numerous standard references.

  • AC ammeter
  • Direct connection or on 1A or 5A CT
  • Normal scale or motor
  • 50 or 60 Hz moving-iron measuring element
  • 50 to 10,000 Hz moving-coil measuring element
  • Deflection 90° or 250°
  • Format 48, 72 or 96
Analogue device

Analogue device

Designed and manufactured

Designed and manufactured

Cost-effective solution

Cost-effective solution

Easy installation

Easy installation

Contact a sales representative

Need information about our solutions? Our experts are available to advise you and assist you with your project. Contact a sales representative now for a detailed presentation and a quote tailored to your needs.

Contact a sales representative

Highlights

  • Reference standard IEC 60051-1
  • Designed for common industrial applications.
  • Technology and cost suitable for manufacturers of machines and electrical switchboards.
  • Numerous items listed.
  • IP52 as standard (IP55 on request)

Features

Function

Classic AC ammeter (CL)

Measurement element

90° deviation

Ferromagnetic, 50 to 60 Hz magnetoelectric with rectifier, 50 to 10,000 Hz

240° deviation

Magnetoelectric with rectifier, 50 to 10,000 Hz

Normal scale

100 mA to 30 A

Engine scale

from 0 to In at 2/3 of the scale, then from 3 to 6 In at the end of the scale (standard value 3 In)

Connection mode

Direct

0 to 30 A

On CT

In: 1 A or 5 A (scale from 0 to 1.3 In)

General specifications

Reference standard

CEI 60051-1

Class index (accuracy class)

01/05/2025

Assembly

On front of panel - Panel thickness 8 mm max.

Format

48x48 mm - 72x72 mm - 96x96 mm

Needle deviation range

90° or 240°

Ingress protection (IP)

IP52 - IP55

Overload ammeter

1.3 In permanent / 10 In for 5 s

Conditions of use

Nominal operating temperature: 23 °C +/- 2 °C.

Operating temperature limit: -25 °C to +50 °C.

Relative humidity: < 90% to 40 °C

Dial Inscription/marking/numbering on request

yes

Documentation and support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

Identify your reference

This downloadable selection guide allows you to identify the item code corresponding to your needs.

CL.AMP.DC_5.png

Add or remove products from your selection directly online, then fill out the form with your contact details. Once your request has been sent, our specialist teams will review it and respond as soon as possible with a solution tailored to your needs.

Classic Ammeter AC 96x96mm 240° 0-150/450A TC 150/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-150/450A TC 150/5A Class 1,5

20759228

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-150/450A TC 150/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-200/600A TC 200/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-200/600A TC 200/5A Class 1,5

20759230

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-200/600A TC 200/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-250/750A TC 250/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-250/750A TC 250/5A Class 1,5

20759231

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-250/750A TC 250/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-300/900A TC 300/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-300/900A TC 300/5A Class 1,5

20759233

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-300/900A TC 300/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-400/1200A TC 400/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-400/1200A TC 400/5A Class 1,5

20759235

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-400/1200A TC 400/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-500/1500A TC 500/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-500/1500A TC 500/5A Class 1,5

20759236

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-500/1500A TC 500/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-600/1800A TC 600/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-600/1800A TC 600/5A Class 1,5

20759238

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-600/1800A TC 600/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-750/2250A TC 750/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-750/2250A TC 750/5A Class 1,5

20759240

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-750/2250A TC 750/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-800/2400A TC 800/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-800/2400A TC 800/5A Class 1,5

20759241

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-800/2400A TC 800/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Classic Ammeter AC 96x96mm 240° 0-1000/3000A TC 1000/5A Class 1,5

Classic Ammeter AC 96x96mm 240° 0-1000/3000A TC 1000/5A Class 1,5

20759242

Classic panel meter AC ammeter - Size 96x96mm - deflection 240° - Measurement range 0-1000/3000A TC 1000/5A - Accuracy class 1.5 - Reference standard IEC 600051-1 - Round barrel with 2 studs for mounting

Request a quote