MEMO P200
Simple, high-performance 96x96 power monitor - Designed for general applications
Manufactured in our French factories, the ENERIUM range of power meters is specifically designed for energy management and electrical optimization in industrial sites and power grids.
Thanks to advanced measurement functions, they enable the analysis of power quality, the correlation of climate data with energy consumption, and the alerting of the user in case of critical electrical parameters being exceeded.
With a compact 144x144mm form factor that easily integrates into electrical cabinets, the ENERIUM 200 power meter is suitable for precise and accurate measurement ( accuracy class 0.2 s) of any HV/MV/LV electrical supply or supply.
Analyzing the behavior of the electrical installation is done in just a few clicks on the ENERIUM 200 screen: alarm log, Fresnel diagram, harmonic analysis by order, etc.
The integrated Ethernet or RS485 communication interfaces allow for remote operation and control of the product.
Its digital and analog inputs and outputs (up to 8) allow for easy integration into a monitoring or control architecture.
Class 0.2s
Standard
Harmonic disturbance meas.
High-readability display
Available inputs/outputs
Contact a sales representative
Need information about our solutions? Our experts are available to advise you and assist you with your project. Contact a sales representative now for a detailed presentation and a quote tailored to your needs.
Enerium and Memo power metering devices are essential tools for minimizing your energy consumption and optimizing your electrical installation in low, medium, or high voltage.
RS485 or Ethernet communication as standard
Energy measurement class 0.2s
Wide choice of analog or digital inputs/outputs
Large ergonomic display
Made in France
Maximum measured phase-to-phase voltage
650 kV
TT ratio
Primary TT: 100 V to 650 kV
Secondary VT: 100 V to 480 V
Max. measured current
25,000 A
CT ratio
Primary CT: 1 A to 25 000 A
Secondary CT: 1 A or 5 A
Max. measured power
2 GW
Measurement range
From 5 to 130% of Vn for Vn = 57.7 / 230 V (ph-N)
From 5 to 130% of Un for Un = 100 / 400 V (ph-ph)
Crest factor
2
Measurement accuracy (U and V)
0.2% from 20% to 130% of Un
.Voltage swell
Transient U = 800 V for 24 hours.
Permanent 130% of 400 V = 520 V
Frequency
50/60 Hz
Consumption
< 0.1 VA
Input impedance
1 MΩ
Measurement range
From 1% to 130% of In for In = 5 A
.Crest factor
3
Measurement accuracy
0.2% of ≥ 10%... ≤ 130%
0.5% of ≥ 5%... ≤ 10%
1% from ≥ 1% to ≤ 5%
Acceptable overload
Transient I = 250 A for 1 second.
130% of 5 A = 6.5 A continuous
Consumption
< 0.15 VA
CEI 62053-21/22
Active energy class 0.2 s
CEI 62053-23/24
Reactive energy class 0.5 s
CEI 61557-12
class 0.5 or class 0.2
PMD SD/SS
Active energy class 0.5 or active energy class 0.2.
Reactive energy class 0.5
Connection
2 wire, half duplex
Protocol
ModBus / JBus RTU mode
Speed (configurable)
2400 - 4800 - 9600 - 19 200 - 34 800
Parity
Even, odd or no parity
Jbus addresses
1 to 247
Type
RJ45 - 8 points
Protocol
ModBus / TCP
Speed (configurable)
Compatible with 10, 100 and 1000 base T networks
Power supply
80 to 265 Vac (< 20 VA)
42.5 to 69 Hz
80 to 265 Vdc
19 to 57 Vdc (< 10 W)
Max number of inputs / outputs
8
Temperature of use
-10 °C to +55 °C (K55 according to IEC 61557-12)
Operating humidity
95 % to 40 °C
Storage temperature
-25 °C to +70 °C
Assembly
Front panel
Size
144 x 144
Language *
Contact support
Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
Language *
Contact support
Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.
To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.
ENERIUM100-CFG
ENERIUM 100 Customizable Power metering device - Size 144x144mm - Individual harmonic analysis measurement - Reference standard IEC 61557-12 - Panel mounting - High-readability display - Accuracy class 0.2s
ENERIUM110-CFG
ENERIUM 110 Customizable Power metering device - Size 144x144mm - Individual harmonic analysis measurement - Reference standard IEC 61557-12 - Accuracy class 0.2s
ENERIUM200-CFG
ENERIUM 200 Customizable Power metering device - 144x144mm format - Individual harmonic analysis measurement - Reference standard IEC 61557-12 - Panel mounting - High-readability display - Accuracy class 0.2s
ENERIUM210-CFG
ENERIUM 210 Customizable Power metering device - 144x144mm format - Individual harmonic analysis measurement - Reference standard IEC 61557-12 - Accuracy class 0.2s
P01330831
ENERIUM 100 Power metering device - Size 144x144mm - Individual harmonic analysis - Modbus RS485 communication - Reference standard IEC 61557-12 - Panel mounting - High-readability display - Accuracy class 0.2s
P01330832
ENERIUM 100 Power metering device - Size 144x144mm - Individual harmonic analysis - Modbus RS485 communication - 2 digital inputs + 2 digital outputs - Reference standard IEC 61557-12 - Accuracy class 0.2s
P01330833
ENERIUM 200 Power metering device - Size 144x144mm - Individual harmonic analysis - Modbus RS485 communication - 4 digital inputs + 2 analog outputs - Reference standard IEC 61557-12 - Accuracy class 0.2s
P01330834
ENERIUM 200 Power metering device - Size 144x144mm - Individual harmonic analysis - Ethernet communication - 2 digital inputs/2 digital outputs + 2 analog outputs - Reference standard IEC 61557-12 - Accuracy class 0.2s
P01330835
ENERIUM 210 Power metering device - Size 144x144mm - Individual harmonic analysis - Ethernet communication - 8 digital inputs - Reference standard IEC 61557-12 - Accuracy class 0.2s
Request a quote
Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.