Product presentation

The NE range of needle indicators is designed to operate in demanding environments: nuclear, hydroelectric, military, Naval vessels, etc.

The range is available in several sizes (48, 72 and 96 mm), several types of measurement quantities, and from IP40 to IP55. These indicators have been installed for decades in critical infrastructure.

Available in many standard references and on specific manufacturing requests.

  • AC ammeter
  • Direct connection or connection via 1A or 5A CT
  • Standard scale or motor
  • Moving-iron measuring element 50, 60 or 400 Hz
  • Moving-coil measuring element 50 to 10,000 Hz
  • Deflection 90° or 250°
  • Format 48, 72 or 96
Analogue device

Analogue device

Designed and manufactured

Designed and manufactured

Nuclear environment

Nuclear environment

Easy installation

Easy installation

Contact a sales representative

Need information about our solutions? Our experts are available to advise you and assist you with your project. Contact a sales representative now for a detailed presentation and a quote tailored to your needs.

Contact a sales representative

Highlights

  • Complies with the IEC 60051-1 reference standard
  • Designed for critical applications: Naval Defense, Nuclear, hydraulics, sensitive industries, etc.
  • Durable and long-lasting.
  • Referenced or customized items
  • Numerous options (IP, mounting method, specific dials, etc.)

Features

Function

AC ammeter NormEurope (NE)

Measurement element

90° deviation

Ferromagnetic 50-60-400 Hz

Magneticelectric with rectifier 50-10,000 Hz

250° deviation

Magnetoelectric with rectifier 50-10 000 Hz

Normal scale

0 to 50 A

Engine scale

from 0 to In at 2/3 of the scale, then from 2 to 6 In at the end of the scale (standard value 3 In)

Connection mode

Direct

0 to 50 A

On CT

In: 1 A or 5 A (scale from 0 to 1.3 In)

General specifications

Reference standard

IEC 60051-1, IEC 60051-2, IEC 60051-9

Class index (accuracy class)

01/05/2025

Assembly

On front of panel - Mounting with 2 or 4 studs or flush-mounting ring

Format

48x48 mm - 72x72 mm - 96x96 mm

Needle deviation range

90 ° or 250 °

Ingress protection (IP)

IP40 - IP52 - IP54 - IP55

Overload ammeter

1.3 In permanent / 10 In for 5s

Conditions of use

Nominal operating temperature: 23 °C +/- 10 °C.

Operating temperature limit: -25 °C to +60 °C.

Relative humidity: 25 to 95% Relative humidity < 90%

Dial Inscription / Marking / Numbering on request

yes

Documentation and support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

Identify your reference

This downloadable selection guide allows you to identify the item code corresponding to your needs.

CL.AMP.DC_5.png

Add or remove products from your selection directly online, then fill out the form with your contact details. Once your request has been sent, our specialist teams will review it and respond as soon as possible with a solution tailored to your needs.

NormEurope Ammeter AC 72x72mm 90° 0-100A TC 75/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-100A TC 75/5A Class 1,5

A90A0316

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-100A TC 75/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-130A TC 100/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-130A TC 100/5A Class 1,5

A90A0317

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-130A TC 100/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-165A TC 125/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-165A TC 125/5A Class 1,5

A90A0318

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-165A TC 125/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-200A TC 150/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-200A TC 150/5A Class 1,5

A90A0319

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-200A TC 150/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-260A TC 200/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-260A TC 200/5A Class 1,5

A90A0320

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-260A TC 200/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-325A TC 250/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-325A TC 250/5A Class 1,5

A90A0321

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-325A TC 250/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-400A TC 300/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-400A TC 300/5A Class 1,5

A90A0322

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-400A TC 300/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-520A TC 400/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-520A TC 400/5A Class 1,5

A90A0323

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-520A TC 400/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-650A TC 500/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-650A TC 500/5A Class 1,5

A90A0324

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-650A TC 500/5A - Accuracy class 1.5

NormEurope Ammeter AC 72x72mm 90° 0-800A TC 600/5A Class 1,5

NormEurope Ammeter AC 72x72mm 90° 0-800A TC 600/5A Class 1,5

A90A0325

NormEurope panel meter AC ammeter - Size 72x72mm - 90° deflection - Measurement range 0-800A TC 600/5A - Accuracy class 1.5

Request a quote

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.