Product presentation

The NE range of needle indicators is designed to operate in demanding environments: nuclear, hydroelectric, military, Naval vessels, etc.

The range is available in several sizes (48, 72 and 96 mm), several types of measurement quantities, and from IP40 to IP55. These indicators have been installed for decades in critical infrastructure.

Available in many standard references and on specific manufacturing requests.

  • Wattmeter or Varmeter
  • Single-phase or three-phase networks
  • Connection to transducer output (T82, T82N, TRIAD)
  • Standard mA or V scale
  • Moving-coil measuring element
  • 90° or 250° deflection
  • 48, 72 or 96 format
Analogue device

Analogue device

Designed and manufactured

Designed and manufactured

Nuclear environment

Nuclear environment

Easy installation

Easy installation

Contact a sales representative

Need information about our solutions? Our experts are available to advise you and assist you with your project. Contact a sales representative now for a detailed presentation and a quote tailored to your needs.

Contact a sales representative

Highlights

  • Complies with the IEC 60051-1 reference standard
  • Designed for critical applications: Naval Defense, Nuclear, hydraulics, sensitive industries, etc.
  • Durable and long-lasting.
  • Referenced or customized items
  • Numerous options (IP, mounting method, specific dials, etc.)

Features

Function

Wattmeter - Varmeter AC NormEurope (NE)

Measurement element

90°-250° deviation

Magnetoelectric 2 mA (or other calibre on request) in combination with a T82N or TRIAD measurement converter

Linear scale

Measurement range on demand (Active kW or Reactive kvar)

Left zero or central zero.

Offset scale

Connection mode

On CT and VT for the associated T82N or TRIAD converter.

At the converter output for the wattmeter pointer indicator or varmeter (mA or Vdc calibre).

General specifications

Reference standard

IEC 60051-1, IEC 60051-2, IEC 60051-9

Class index (accuracy class)

01/05/2025

Assembly

On front of panel - Mounting with 2 or 4 studs or flush-mounting ring

Format

72x72 mm - 96x96 mm

Needle deviation range

90 ° or 250 °

Ingress protection (IP)

IP40 - IP52 - IP54 - IP55

Voltage and current overload

According to the specifications of the associated converter

Conditions of use

Nominal operating temperature: 23 °C +/- 10 °C.

Operating temperature limit: -25 °C to +60 °C.

Relative humidity: 25 to 95% Relative humidity < 90%

Dial Inscription / Marking / Numbering on request

yes

Documentation and support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

Identify your reference

This downloadable selection guide allows you to identify the item code corresponding to your needs.

CL.AMP.DC_5.png

Add or remove products from your selection directly online, then fill out the form with your contact details. Once your request has been sent, our specialist teams will review it and respond as soon as possible with a solution tailored to your needs.

picto

NormEurope Power Panel meter Customizable Class 1,5

IA-_NEPUIS

Wattmeter and varmeter - Single-phase or three-phase network - 90° or 250° deflection

NormEurope wattmeter 96x96mm 90° 40/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 40/5A 380V 50Hz Class 1,5

WV905001

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 40/5A 380V 50Hz - Accuracy class 1.5

NormEurope wattmeter 96x96mm 90° 60/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 60/5A 380V 50Hz Class 1,5

WV905002

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 60/5A 380V 50Hz - Accuracy class 1.5

NormEurope wattmeter 96x96mm 90° 0-60KW 100/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 0-60KW 100/5A 380V 50Hz Class 1,5

WV905003

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 0-60KW 100/5A 380V 50Hz - Accuracy class 1.5

NormEurope wattmeter 96x96mm 90° 150/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 150/5A 380V 50Hz Class 1,5

WV905004

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 150/5A 380V 50Hz - Accuracy class 1.5

NormEurope wattmeter 96x96mm 90° 250/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 250/5A 380V 50Hz Class 1,5

WV905005

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 250/5A 380V 50Hz - Accuracy class 1.5

NormEurope wattmeter 96x96mm 90° 400/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 400/5A 380V 50Hz Class 1,5

WV905006

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 400/5A 380V 50Hz - Accuracy class 1.5

NormEurope wattmeter 96x96mm 90° 600/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 600/5A 380V 50Hz Class 1,5

WV905007

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 600/5A 380V 50Hz - Accuracy class 1.5

NormEurope wattmeter 96x96mm 90° 1000/5A 380V 50Hz Class 1,5

NormEurope wattmeter 96x96mm 90° 1000/5A 380V 50Hz Class 1,5

WV905008

NormEurope panel meter wattmeter - Size 96x96mm - 90° deflection - Measurement range 1000/5A 380V 50Hz - Accuracy class 1.5

Request a quote

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.