Model

TRC 10: wound primary, ranges 25 x 25 mm  

TCR 15: primary winding, 16 mm² wire

General specifications

Reference standard

IEC 61869-1, IEC 61869-2, UL94

Highest voltage in the network

720 Vac

Dielectric test voltage

3 kV/50 Hz/1 min

Frequency response

50/60 Hz

Thermal short circuit current (Ith)

60 In - 1 second

Dynamic current (Idyn)

2.5 Ith

Safety factor

< 5

Conditions of use

Temperature: -10 °C to +50 °C, Relative humidity < 90%.

Primary current:

TCR 10: 5-125 A 

TCR 15: 5-50 A

Power

TCR 10: 15 VA for class 0.5 s  

TCR 15: 2.5 VA for class 0.5 s

Documentation and support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

Identify your reference

This downloadable selection guide allows you to identify the item code corresponding to your needs.

 

Add or remove products from your selection directly online, then fill out the form with your contact details. Once your request has been sent, our specialist teams will review it and respond as soon as possible with a solution tailored to your needs.

TCR 10 Current transformer 5/5A 20VA Class 1

TCR 10 Current transformer 5/5A 20VA Class 1

19201507

TCR 10 Current transformer with wound primary - Transformation ratio 5/5A - Precision power 20VA - Accuracy class 1

TCR 10 Current transformer 10/5A 20VA Class 1

TCR 10 Current transformer 10/5A 20VA Class 1

19201512

TCR 10 Current transformer with wound primary - Transformation ratio 10/5A - Precision power 20VA - Accuracy class 1

TCR 10 Current transformer 60/5A 20VA Class 1

TCR 10 Current transformer 60/5A 20VA Class 1

19201521

TCR 10 Current transformer with wound primary - Transformation ratio 60/5A - Precision power 20VA - Accuracy class 1

TCR 10 Current transformer 75/5A 20VA Class 1

TCR 10 Current transformer 75/5A 20VA Class 1

19201523

TCR 10 Current transformer with wound primary - Transformation ratio 75/5A - Precision power 20VA - Accuracy class 1

TCR 10 Current transformer 125/5A 20VA Class 1

TCR 10 Current transformer 125/5A 20VA Class 1

19201526

TCR 10 Current transformer with wound primary - Transformation ratio 125/5A - Precision power 20VA - Accuracy class 1

TCR 15 Current transformer 5/5A 5VA Class 1

TCR 15 Current transformer 5/5A 5VA Class 1

19201707

TCR 15 Current transformer with wound primary - Transformation ratio 5/5A - Precision power 5VA - Accuracy class 1

TCR 15 Current transformer 10/5A 5VA Class 1

TCR 15 Current transformer 10/5A 5VA Class 1

19201712

TCR 15 Current transformer with wound primary - Transformation ratio 10/5A - Precision power 5VA - Accuracy class 1

TCR 15 Current transformer 15/5A 5VA Class 1

TCR 15 Current transformer 15/5A 5VA Class 1

19201714

TCR 15 Current transformer with wound primary - Transformation ratio 15/5A - Precision power 5VA - Accuracy class 1

TCR 15 Current transformer 20/5A 5VA Class 1

TCR 15 Current transformer 20/5A 5VA Class 1

19201715

TCR 15 Current transformer with wound primary - Transformation ratio 20/5A - Precision power 5VA - Accuracy class 1

TCR 15 Current transformer 25/5A 5VA Class 1

TCR 15 Current transformer 25/5A 5VA Class 1

19201716

TCR 15 Current transformer with wound primary - Transformation ratio 25/5A - Precision power 5VA - Accuracy class 1

Request a quote

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.