Product presentation

Range of low voltage current transformers with cable/busbar primary for submetering, capable of measuring alternating current from 40 to 3000A, available in 5 models.

  • The TCR20 model from 40 to 200A class 0.5 with cable primary Ø 20 mm
  • The TCR22-30 model from 100 to 400A class 0.5 model with cable primary Ø 22 mm / busbar primary 25 x 10 - 30 x 10 - 20 x 12 mm
  • The TCR28-40 model from 150 to 600A class 0.5 model with cable primary Ø 28 mm / busbar primary 20 x 25 - 30 x 15 - 40 x 10 mm
  • The TCR43-60 model from 400 to 1200A class 0.5 model with cable primary Ø 43 mm / busbar primary 50 x 30 - 60 x 12 - 12 x 45 mm
  • The TCR63-80 model from 1500 to 3000A class 0.5 model with cable primary Ø 63mm / busbar primary 50 x 50 - 60 x 30 - 80 x 30 mm

The transformers are supplied with mounting accessories for clamping on busbars and equipped with outputs on split terminals allowing the secondary to be short-circuited for risk-free commissioning.

Our range complies with IEC 61869-1, IEC 61869-2

Contact a sales representative

Need information about our solutions? Our experts are available to advise you and assist you with your project. Contact a sales representative now for a detailed presentation and a quote tailored to your needs.

Contact a sales representative

Highlights

  • Compact design
  • Outputs on split terminals allowing the secondary to be short-circuited

Features

Model

TCR 20: Ø 20 mm cable passage  

TCR 22-30: Ø 22 mm cable passage / bar passage: 25 x 10 | 30 x 10 | 20 x 12 (mm)  

TCR 28-40: cable passage Ø 28 mm / bar passage: 20 x 25 | 30 x 15 | 40 x 10 (mm)  

TCR 43-60: cable passage Ø 43 mm / bar passage: 50 x 30 | 60 x 12 | 12 x 45 (mm)  

TCR 63-80: cable passage Ø 63 mm / bar passage: 50 x 50 | 60 x 30 | 80 x 30 (mm)

General specifications

Reference standard

IEC 61869-1, IEC 61869-2, UL94

Highest voltage in the network

720 Vac

Dielectric test voltage

3 kV/50 Hz/1 min

Frequency response

50/60 Hz

Thermal short circuit current (Ith)

60 In - 1 second

Dynamic current (Idyn)

2.5 Ith

Safety factor

< 5

Working temperature

Thermal class B (130°C)

Plastic housing

V0 self-extinguishing UL94

Degree of protection for secondary terminals

IP20

Conditions of use

Temperature: -5 °C and +40 °C. Relative humidity < 90%.

Primary current:

TCR 20: 40-200/5 A  

TCR 22-30: 100-400/5 A  

TCR 28-40: 150-600/5 A  

TCR 43-60: 400-1200/5 A  

TCR 63-80: 1500-3000/5 A

Power

TCR 20: from 1.5 to 5 VA for class 0.5 s  

TCR 22-30: from 1 to 2.5 VA for class 0.5 s  

TCR 28-40: from 1 to 5 VA for class 0.5 s  

TCR 43-60: from 2.5 to 5 VA for class 0.5 s  

TCR 63-80: 5 VA for class 0.5 s

Documentation and support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

Language *

Contact support

Have a question about using or installing your equipment? Our support team is available to provide you with quick and effective solutions. Contact support for personalized assistance.

Contact support

References and accessories

To fully meet your expectations, a range of accessories is available that is compatible with your equipment. Feel free to add them to your quote request to obtain a complete and tailored solution.

Identify your reference

This downloadable selection guide allows you to identify the item code corresponding to your needs.

TCR 22-30 Current transformer 150/5A 1VA Class 0,5

TCR 22-30 Current transformer 150/5A 1VA Class 0,5

P01340210

TCR 22-30 Current transformer with busbar and cable passage, diameter 22 mm - Transformation ratio 150/5 A - Precision power 1 VA - Accuracy class 0.5

TCR 22-30 Current transformer 200/5A 1,5VA Class 0,5

TCR 22-30 Current transformer 200/5A 1,5VA Class 0,5

P01340211

TCR 22-30 Current transformer with 22 mm diameter busbar and cable feed - Transformation ratio 200/5A - Precision power 1.5VA - Accuracy class 0.5

TCR 22-30 Current transformer 250/5A 2,5VA Class 0,5

TCR 22-30 Current transformer 250/5A 2,5VA Class 0,5

P01340212

TCR 22-30 Current transformer with busbar and cable feed-through, diameter 22 mm - Transformation ratio 250/5 A - Precision power 2.5 VA - Accuracy class 0.5

TCR 22-30 Current transformer 300/5A 2,5VA Class 0,5

TCR 22-30 Current transformer 300/5A 2,5VA Class 0,5

P01340213

TCR 22-30 Current transformer with busbar and cable connection, diameter 22 mm - Transformation ratio 300/5 A - Precision power 2.5 VA - Accuracy class 0.5

TCR 22-30 Current transformer 400/5A 2,5VA Class 0,5

TCR 22-30 Current transformer 400/5A 2,5VA Class 0,5

P01340214

TCR 22-30 Current transformer with busbar and cable feed-through, diameter 22 mm - Transformation ratio 400/5 A - Accuracy class 0.5 - Accuracy class 0.5

TCR 28-40 Current transformer 150/5A 1VA Class 0,5

TCR 28-40 Current transformer 150/5A 1VA Class 0,5

P01340215

TCR 28-40 Current transformer with busbar and cable feed-through, diameter 28 mm - Transformation ratio 150/5 A - Precision power 1 VA - Accuracy class 0.5

TCR 28-40 Current transformer 200/5A 1,5VA Class 0,5

TCR 28-40 Current transformer 200/5A 1,5VA Class 0,5

P01340216

TCR 28-40 Current transformer with busbar and cable feed-through, diameter 28 mm - Transformation ratio 200/5 A - Precision power 1.5 VA - Accuracy class 0.5

TCR 28-40 Current transformer 250/5A 2,5VA Class 0,5

TCR 28-40 Current transformer 250/5A 2,5VA Class 0,5

P01340217

TCR 28-40 Current transformer with busbar and cable feed-through, diameter 28 mm - Transformation ratio 250/5 A - Precision power 2.5 VA - Accuracy class 0.5

TCR 28-40 Current transformer 300/5A 2,5VA Class 0,5

TCR 28-40 Current transformer 300/5A 2,5VA Class 0,5

P01340218

TCR 28-40 Current transformer with busbar and cable feed-through, diameter 28 mm - Transformation ratio 300/5A - Precision power 2.5VA - Accuracy class 0.5

TCR 28-40 Current transformer 400/5A 2,5VA Class 0,5

TCR 28-40 Current transformer 400/5A 2,5VA Class 0,5

P01340219

TCR 28-40 Current transformer with busbar and cable feed-through, diameter 28 mm - Transformation ratio 400/5 A - Precision power 2.5 VA - Accuracy class 0.5

Request a quote

Add one or more products to your quote request in just a few clicks. Our teams will analyze your needs and get back to you quickly with a personalized offer tailored to your requirements.