8 result(s) :

Qual-SRT & Qual-View

Software for configuration, real-time display and analysis for measurement campaigns with MAP607 and MAP COMPACT network analyzers

The Qual-SRT software can be used for configuration and real-time display on the MAP607:

  • Measurements from the MAP607's two channels
  • The number of voltage dips / overvoltages / long outages / brief outages / transients recorded
  • Global status of the last EN50160 report
  • Memory occupation rate
  • Equipment date and time

Dynamic views are also available: graph of trends (logger-type view)  and harmonics bargraph up to 50th order. Thanks to the self-declaring ultra-fast USB2.0 link, this module can also be used for near-instantaneous data recovery and deletion of the data in the equipment.

The Qual-SRTc software can be used for configuration and real-time display on MAP COMPACT:

  • Measurements of electrical parameters with display of Fresnel diagram and harmonics bargraph
  • Total of the active, reactive and apparent energy indices
  • Memory occupation rate
  • Equipment date and time


The Qual-View software is the analysis and report generation tool for MAP COMPACT and MAP607:

It offers a veiw of all the trend curves generatedby the equipment, with the possibility of zooming and graphical display of the limits of the qualimetric template for each parameter.

Event-related views with the event signature, waveform and time/date-stamped events log are also available via dedicated tabs in Qual-View.

setupqualsrt_v1.1.5.13.zip
setupqualsrtc_v1.2.6.1.zip
setupqualview_v1.3.6.16.zip

TRIADJUST2

TRIAD2 configuration software

TRIADJUST 2 can be used for:

Configuration

– Inputs (define the CTs, the VTs, connection diagram, etc.)

– Outputs (define the different channels, transfer functions, class, etc.)

– Communication

Diagnostics

– Voltage inputs

– Current inputs

– Wiring

– Phase sequence

– Analog outputs

– Fresnel diagram

Views

– Instantaneous quantities (in digital or analog form)

Recordings

– In real time in exported file

tradjust2_1_2_0_0.rar

ELOG Excel Macro

Remote data retrieval and analysis application for the data from ELOG.

The excel macro for ELOG allows you to use the standard excel spreadsheet software (version 2010 or 2013) for quick and easy processing of the recordings from ELOG.

Users can retrieve, display and analyze the data recorded on the metering and measuring equipment connected to an ELOG.

 The application can be used to:

  • connect remotely to an ELOG by means of its IP address
  • view and select all or some of the variables recorded
  • retrieve the recorded data and present them in a table (recording date and time / value)
  • produce an analytical table of the data (calculation of hourly or daily values)
  • produce pre-configured graphs for analysis of the recordings

From the Excel spreadsheet, it is easy for users to:

  • modify the tables and graphs
  • customize presentation of the results
  • export the data in .txt, .csv, .xls or other format for third-party applications

The code of the Excel macro is open-source, so any user can freely upgrade or modify it.

macro_v1.0_elog_release_5.xlsm_.zip

E.VIEW

Configuration and display software for your ENERIUM power monitor

E.view software is an essential tool for configuring your ENERIUM power monitor and viewing the information from it.

This software can be used to:

  • Program the communication parameters of the products (address, speed, parity, etc.) and the setup parameters (CT ratio, VT ratio, alarm thresholds, etc.)
  • Configure the power monitors in the ENERIUM range remotely, via the RS485 network or Ethernet network, or via the local area network  with the optical head
  • View all the quantities managed by the power monitor (1 s reading, averages, time/date-stamped min and max)
  • Optimize multi-product management by creating and displaying the architecture of the electrical installation
  • Process the data:
    • Summary tables: simplified summary of the results, alarms log, compliance of statistics with EN50160, time/date-stamped events (dips, outages, overvoltages, etc.)
    • Data export: alarms log, EN50160 statistics, voltage events (dips, outages, overvoltages, etc.) and waveforms, all in .CSV, .XLS or .TXT format
e.view_1.5.2.0.zip

Excel macro for ELOG DATA LOGGER

Excel macro to provide the following functions:

- Remote download of the recorded data from the ELOG DATA LOGGER

- Analysis of the recorded data in preconfigured graphs or tables

macro_elog_data_logger_20160624.zip

FAQs

faq01_-_how_to_choose_your_current_transformer_eng.pdf How to choose your Current Transformer
faq02_-_how_to_optimize_the_choice_of_your_current_transformer_eng.pdf How to optimize the choice of your Current Transformer
faq03_ulys_tt_-_quick_commisioning_eng.pdf ULYS TT - Quick commisioning
faq04_ulys_tta_-_quick_commisioning_eng.pdf ULYS TTA - Quick commisioning
faq05_-_how_to_choose_your_energy_meter_eng.pdf How to choose your energy meter
faq06_ulys_ttx_-_checking_the_installation_of_a_ulys_ttx_eng.pdf ULYS TTx - Checking the installation of a ULYS TTx
faq07_-_how_to_find_out_the_accuracy_class_of_my_measuring_equipment_eng.pdf How to find out the accuracy class of my measuring equipment
faq08_-_what_class_do_i_need_for_the_sensors_linked_to_my_measuring_system_eng.pdf What class do I need for the sensors linked to my measuring system
faq09_ca2150_-_how_to_communicate_with_your_ca2150_eng.pdf How to communicate with your CA2150
faq10_ulys_-_how_to_read_a_ulys_meter_tda80td80_tta_tt_eng.pdf How to read a ULYS meter TDA80,TD80, TTA ,TT
faq11-_which_communication_mode_should_you_choose_to_dialog_with_your_energy_meters_eng.pdf Which communication mode should you choose to dialog with your energy meters
faq12_ulys_flex_-_quick_commisioning_eng.pdf ULYS Flex - Quick commisioning
faq13_ulys_flex_-_checking_the_operation_of_a_ulys_flex_eng.pdf ULYS Flex - Checking the operation of a Ulys Flex
faq14_ulys_tt-m_-_setting_the_communication_parameters_for_your_ulys_tt-m_modbus_meter_eng.pdf ULYS TT-M - Setting the communication parameters for your ULYS TT-M MODBUS meter
faq15_ulys_flex_-_setting_the_communication_parameters_for_your_ulys_flex_meter_eng.pdf ULYS FLEX - Setting the communication parameters for your ULYS FLEX meter
faq16_ulys_mcm_-_commissioning_eng.pdf

Ulys MCM Utility

Ulys MCM Utility is the configuration and real-time display software for Ulys MCM

  • Ulys MCM Utility allows users to configure the setting and check the data of each load very simply
  • Read and Record the parameter settings for the Ulys MCM Utility software
  • Load and Save the parameter settings from a file

 

  • Scan the network to find the instruments' IP addresses
  • Add or delete an instrument in the tree structure
  • Modify the settings of the Ulys MCM (general settings and settings for each of the electrical feeders)
  • View the TX/TX communication frames with the instruments

 

  • Monitor the data measured by the ULYS MCM for each electrical feeder
  • Display on a single screen all the quantities measured on all the electrical feeders
  • Display the main information on the electrical feeders in graph form in real time
  • Display the historical data concerning the electrical feeders in graph format
setup_v1.01_20200709.zip

Windows Optical Head Driver / USB CP210x

Universal Windows Driver v10.1.10 du 13/01/2021

For optical head for Enerium 50/150, Triad2 et Elog Data Logger reference P01330403
For optical head for pour Enerium 1x0/2x0/3x0 reference P01330401
cp210x_universal_windows_driver.zip